1,239 research outputs found

    Analyse par simulation de l’interaction entre un jet plasma et des gouttes de suspension colloïdale : application à la projection plasma de nanomatériaux

    Get PDF
    L'objectif de ce travail consiste à modéliser les interactions hydrodynamiques, thermiques et physico chimiques entre un jet de plasma à haute température et un jet liquide chargé en particules nanométriques. La projection plasma de nanomatériaux est une voie industrielle qui permet d'obtenir des dépôts denses épais (environ dix microns, voire plus) aux propriétés accrues. Ce procédé fait l'objet de recherches approfondies tant les potentialités industrielles sont nombreuses. Sa modélisation requiert de scinder l'écoulement à plasma en zones géographiques correspondant aux étapes du procédé : -l'injection de la phase porteuse des particules dans laquelle le jet continu ou les trains de gouttes viennent pénétrer le jet de plasma et donner lieu à la fragmentation primaire et secondaire de la phase liquide. Des travaux antérieurs ont porté sur cette étape. -L’évaporation de la phase porteuse -Les interactions particule/plasma -L’étape d'impact et de fabrication du dépôt que nous n’étudierons pas. La fabrication du revêtement dépend fortement des étapes précédentes. A partir des travaux précédents, nous modéliserons l'évolution thermocinétique des gouttes et particules sur des échelles allant du micron au millimètre avec les mécanismes spécifiques liés au changement de phase liquide/solide, à la mouillabilité sur les particules solides, aux lignes triples et à l'interaction particule/écoulement di/triphasique. Il s'agira de simuler à une échelle locale les écoulements multiphasiques et les transferts de chaleur, par des méthodes VOF et un modèle 1 fluide compressible, et d'étudier l'évolution thermocinétique des particules et de la phase porteuse. L’intérêt de ce travail est de fournir des éléments de compréhension du procédé et de contrôle des propriétés du dépôt

    Inference and Visualization of Information Flow in the Visual Pathway using dMRI and EEG

    Get PDF
    International audienceWe propose a method to visualize information flow in the visual pathway following a visual stimulus. Our method estimates structural connections using diffusion magnetic resonance imaging and functional connections using electroencephalography. First, a Bayesian network which represents the cortical regions of the brain and their connections is built from the structural connections. Next, the functional information is added as evidence into the network and the posterior probability of activation is inferred using a maximum entropy on the mean approach. Finally, projecting these posterior probabilities back onto streamlines generates a visual depiction of pathways used in the network. We first show the effect of noise in a simulated phantom dataset. We then present the results obtained from left and right visual stimuli which show expected information flow traveling from eyes to the lateral geniculate nucleus and to the visual cortex. Information flow visualiza-tion along white matter pathways has potential to explore the brain dynamics in novel ways

    Urinary C-Peptide of Insulin as a Non-Invasive Marker of Nutritional Status: Some Practicalities

    Get PDF
    Nutritional status is a critical element of many aspects of animal ecology, but has proven difficult to measure non-invasively in studies of free-ranging animals. Urinary C-peptide of insulin (UCP), a small polypeptide cleaved in an equimolar ratio from proinsulin when the body converts it to insulin, offers great promise in this regard, and recent studies of several non-human primate species have utilized it with encouraging results. Despite this, there are a number of unresolved issues related to the collection, processing, storage and transport of samples. These include: contamination of samples on collection (most commonly by dirt or faeces), short-term storage before returning to a field station, differences in processing and long-term storage methods (blotting onto filter paper, freezing, lyophilizing), and for frozen samples, transportation while keeping samples frozen. Such issues have been investigated for urine samples in particular with respect to their effects on steroid hormone metabolites, but there has been little investigation of their effects on UCP measurement. We collected samples from captive macaques, and undertook a series of experiments where we systematically manipulated samples and tested the effects on subsequent UCP measurements. We show that contamination of urine samples by faeces led to a decrease in UCP levels by >90%, but that contamination with dirt did not have substantial effects. Short-term storage (up to 12 hours) of samples on ice did not affect UCP levels significantly, but medium-term storage (up to 78 hours) did. Freezing and lyophilization for long-term storage did not affect UCP levels, but blotting onto filter paper did. A transportation simulation showed that transporting frozen samples packed in ice and insulated should be acceptable, but only if it can be completed within a period of a few days and if freeze-thaw can be avoided. We use our data to make practical recommendations for fieldworkers

    Phenoloxidase activity acts as a mosquito innate immune response against infection with semliki forest virus

    Get PDF
    Several components of the mosquito immune system including the RNA interference (RNAi), JAK/STAT, Toll and IMD pathways have previously been implicated in controlling arbovirus infections. In contrast, the role of the phenoloxidase (PO) cascade in mosquito antiviral immunity is unknown. Here we show that conditioned medium from the Aedes albopictus-derived U4.4 cell line contains a functional PO cascade, which is activated by the bacterium Escherichia coli and the arbovirus Semliki Forest virus (SFV) (Togaviridae; Alphavirus). Production of recombinant SFV expressing the PO cascade inhibitor Egf1.0 blocked PO activity in U4.4 cell- conditioned medium, which resulted in enhanced spread of SFV. Infection of adult female Aedes aegypti by feeding mosquitoes a bloodmeal containing Egf1.0-expressing SFV increased virus replication and mosquito mortality. Collectively, these results suggest the PO cascade of mosquitoes plays an important role in immune defence against arboviruses

    Towards a Model of Corporate and Social Stakeholder Engagement: Analyzing the Relations Between a French Mutual Bank and Its Members

    No full text
    International audienceThe aim of this article is to develop a new classification of stakeholders based on the concept of corporate and social engagement. Engagement is analyzed as an organizational learning process between the managers of an organization and its stakeholders. It is a necessary condition to improve the organization's impact on its economic, social, and natural environment. Applied to the membership of a French mutual bank in order to identify the members' varying levels of engagement, this new mapping technique may help managers to adapt their practices to the degree of engagement of each identified group of members, and to modify their financial products and communications to foster engagement among as many of these groups as possible

    1989 as a mimetic revolution: Russia and the challenge of post-communism

    Get PDF
    Various terms have been used to describe the momentous events of 1989, including Jürgen Habermas’s ‘rectifying revolution,’ and my own notion of 1989 as a type of ‘anti-revolution’: repudiating not only what had come before, but also denying the political logic of communist power, as well as the emancipatory potential of revolutionary socialism in its entirety. In the event, while the negative agenda of 1989 has been fulfilled, it failed in the end to transcend the political logic of the systems that collapsed at that time. This paper explores the unfulfilled potential of 1989. Finally, 1989 became more of a counter- rather than an anti-revolution, replicating in an inverted form the practices of the mature state socialist regimes. The paucity of institutional and intellectual innovation arising from 1989 is striking. The dominant motif was ‘returnism,’ the attempt to join an established enterprise rather than transforming it. Thus, 1989 can be seen as mimetic revolution, in the sense that it emulated systems that were not organically developed in the societies in which they were implanted. For Eastern Europe ‘returning’ to Europe appeared natural, but for Russia the civilizational challenge of post-communism was of an entirely different order. There could be no return, and instead of a linear transition outlined by the classic transitological literature, Russia’s post-communism demonstrated that the history of others could not be mechanically transplanted from one society to another

    A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS). Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre.</p> <p>Methods</p> <p>A custom made neck jig device is presented as well as the results of a pilot study.</p> <p>The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned.</p> <p>Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation.</p> <p>Results</p> <p>The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife contact with femoral head, positive. There were no guide failures. The jig unique position and the number of steps required to put the guide in place were rated 1, while the complexity to put the guide into place was rated 1-2. In all five cases the guide wire was accurately positioned. Maximum angular deviation was 2.9° and maximum distance between insertion points was 2.1 mm.</p> <p>Conclusions</p> <p>Pilot testing of a custom made jig for use during SRA indicated that the device was (1) successfully applied and user friendly and (2) allowed for accurate guide wire placement according to the preoperative plan.</p

    Seroprevalence of malaria in inhabitants of the urban zone of Antananarivo, Madagascar

    Get PDF
    BACKGROUND: Antananarivo, the capital of Madagascar, is located at an altitude of over 1,200 m. The environment at this altitude is not particularly favourable to malaria transmission, but malaria nonetheless remains a major public health problem. The aim of this study was to evaluate exposure to malaria in the urban population of Antananarivo, by measuring the specific seroprevalence of Plasmodium falciparum. METHODS: Serological studies specific for P. falciparum were carried out with an indirect fluorescent antibody test (IFAT). In a representative population of Antananarivo, 1,059 healthy volunteers were interviewed and serum samples were taken. RESULTS: The seroprevalence of IgG+IgA+IgM was 56.1% and that of IgM was 5.9%. The major risk factor associated with a positive IgG+IgA+IgM IFAT was travel outside Antananarivo, whether in the central highlands or on the coast. The abundance of rice fields in certain urban districts was not associated with a higher seroprevalence. CONCLUSION: Malaria transmission levels are low in Antananarivo, but seroprevalence is high. Humans come into contact with the parasite primarily when travelling outside the city. Further studies are required to identify indigenous risk factors and intra-city variations more clearly

    Canine respiratory coronavirus employs caveolin-1-mediated pathway for internalization to HRT-18G cells

    Get PDF
    Canine respiratory coronavirus (CRCoV), identified in 2003, is a member of the Coronaviridae family. The virus is a betacoronavirus and a close relative of human coronavirus OC43 and bovine coronavirus. Here, we examined entry of CRCoV into human rectal tumor cells (HRT-18G cell line) by analyzing co-localization of single virus particles with cellular markers in the presence or absence of chemical inhibitors of pathways potentially involved in virus entry. We also targeted these pathways using siRNA. The results show that the virus hijacks caveolin-dependent endocytosis to enter cells via endocytic internalization

    Measurement of Beam-Spin Asymmetries for Deep Inelastic π+\pi^+ Electroproduction

    Full text link
    We report the first evidence for a non-zero beam-spin azimuthal asymmetry in the electroproduction of positive pions in the deep-inelastic region. Data have been obtained using a polarized electron beam of 4.3 GeV with the CLAS detector at the Thomas Jefferson National Accelerator Facility (JLab). The amplitude of the sinϕ\sin\phi modulation increases with the momentum of the pion relative to the virtual photon, zz, with an average amplitude of 0.038±0.005±0.0030.038 \pm 0.005 \pm 0.003 for 0.5<z<0.80.5 < z < 0.8 range.Comment: 5 pages, RevTEX4, 3 figures, 2 table
    corecore